EN | 86 Installation and Operating Manual | VIP X1
Configuration using a Web browser Bosch Security Systems | 2006-12 | V2.5
– Click Set after entering a new IP address.
– To restart the unit, enter the old IP address followed by /reset (for example
192.168.0.30/reset) in the address bar of your Web browser. The
VIP X1 restarts, after which it can only be accessed at the new IP address.
IP address:
Enter the desired IP address for the VIP X1 in this field. The IP address must be
valid for the network.
Subnet mask:
Enter the appropriate subnet mask for the selected IP address here.
Gateway address:
If you want the unit to establish a connection to a remote location in a different
subnet, enter the IP address of the gateway here. Otherwise leave the box blank
(0.0.0.0).
Video transmission:
If the unit is operated behind a firewall, TCP (HTTP port) should be selected as
the transfer protocol. For use in a local network, select UDP.
Caution
Multicast operation is only possible with the UDP protocol. The TCP pro-
tocol does not support multicast connections.
Note
The MTU value in UDP mode is 1514 bytes.
HTTP browser port:
Select a different HTTP browser port from the list if required. The default HTTP
port is 80. If you want to limit connection to HTTPS you must deactivate the
HTTP port. To do this activate the Off option.