Relay
You can configure the switching behavior of the relay output. You can specify an
open switch relay (normally closed contact) or a closed switch relay (normally
open contact).
You can also specify whether the output should operate as a bistable or
monostable relay. In bistable mode, the triggered state of the relay is main-
tained. In monostable mode, you can set the time after which the relay will return
to the idle state.
You can select different events that automatically activate the output. It is possi-
ble, for example, to turn on a floodlight by triggering a motion alarm and then
turning the light off again when the alarm has stopped.
Idle state:
Select Open if you want the relay to operate as an NO contact, or select Closed
if the relay is to operate as an NC contact.
Operating mode:
Select an operating mode for the relay.
For example, if you want an alarm-activated lamp to stay on after the alarm
ends, select Bistable. If you wish an alarm-activated siren to sound for 10 sec-
onds, for example, select 10 sec.