Thanks to its ultra-compact dimensions, the VIP X1 is particularly well suited to
installation in cabinets.
Caution
The unit is intended for use indoors or in housings. Select a suitable loca-
tion for installation where the unit will not be subjected to conditions of ex-
treme temperature or humidity. The ambient temperature must be be-
tween 0 and +50°C (+32 and +122°F); the relative humidity must not
exceed 80%.
The unit generates heat during operation, so you should ensure that there
is adequate ventilation and enough clearance between the unit and heat-
sensitive objects or equipment.
Please ensure the following installation conditions:
❚ Do not install the unit close to heaters or other heat sources. Avoid locations
exposed to direct sunlight.
❚ Allow sufficient space for running cables.
❚ Ensure that the unit has adequate ventilation.
❚ When making connections, use only the cables supplied or use appropriate
cables immune to electromagnetic interference.
❚ Position and run all cables so that they are protected from damage, and pro-
vide adequate cable strain relief where needed.
❚ Avoid impacts, blows and severe vibrations as these can irreparably damage