Bosch Appliances VIP X1 Security Camera User Manual


 
EN | 48 Installation and Operating Manual | VIP X1
Configuration using a Web browser Bosch Security Systems | 2006-12 | V2.5
JPEG posting
You can save individual JPEG images on an FTP server at certain intervals.
You can then retrieve these images at a later date to reconstruct alarm events if
required.
JPEG format:
Select the resolution you wish the JPEG images to have:
Small 176 × 144/120 pixels (QCIF)
Medium 352 × 288/240 pixels (CIF)
Large 704 × 576/480 pixels (4CIF)
File name:
You can select how file names will be created for the individual images which
are transmitted.
Overwrite: The same file name is always used and any existing file will be
overwritten with the current file.
Increment: A number from 000 to 255 is added to the file name and automat-
ically incremented by 1. When it reaches 255 it starts again from 000.
Date/time suffix: The date and time are automatically added to the file name.
When setting this parameter, ensure that the unit's date and time are always
correctly set. Example: the file snap011005_114530.jpg was stored on Octo-
ber 1, 2005 at 12.45 p.m. and 30 seconds.