Bosch Appliances VIP X1 Security Camera User Manual


 
EN | 124 Installation and Operating Manual | VIP X1
Appendix Bosch Security Systems | 2006-12 | V2.5
General malfunctions
Malfunction Possible causes Solution
No connection
between the unit and
terminal program.
Incorrect cable connections. Check all cables, plugs, contacts,
terminals and connections.
The computer's serial inter-
face is not connected.
Check the other serial interface.
Interface parameters do not
match.
If necessary select a different inter-
face and make sure that the com-
puter's interface parameters match
those of the unit. Try the following
standard parameters:
19,200 baud, 8 data bits, no parity,
1 stop bit. Next, disconnect the unit
from the power supply and recon-
nect it again after a few seconds.
No image transmis-
sion to remote sta-
tion.
Camera error. Connect local monitor to the cam-
era and check the camera function.
Faulty cable connections. Check all cables, plugs, contacts
and connections.
No connection estab-
lished, no image
transmission.
The unit's configuration. Check all configuration parame-
ters.
Faulty installation. Check all cables, plugs, contacts
and connections.
Wrong IP address. Check the IP addresses
(terminal program).
Faulty data transmission
within the LAN.
Check the data transmission with
ping.
The maximum number of
connections has been
reached.
Wait until there is a free connection
and then call the sender again.
No audio transmis-
sion to remote sta-
tion.
Hardware fault. Check that all connected audio
units are operating correctly.
Faulty cable connections. Check all cables, plugs, contacts
and connections.
Incorrect configuration. Check the audio parameters on the
Audio settings and Livepage
configuration configuration
pages.
The audio voice connection
is already in use by another
receiver.
Wait until the connection is free
and then call the sender again.