Chapter 9 Operational Settings
Appendix
Glossary
Introduction
Index
Contents
TOP
161
How to Load
Documents
Configuring the
Scan Settings
How to Use the
Operator Panel
Various Ways to
Scan
Daily Care
Troubleshooting
Replacing the
Consumables
Scanner
Overview
Operational
Settings
*1: Displayed when using the fi-6230Z or fi-6240Z.
*2: Displayed when the imprinter is installed.
Item Description Parameter/Value Factory Default
Page Counter
(page 166)
Check the counters to determine when to replace
the consumables.
Also use it to reset the counters after replacing the
consumables.
Total Page Count(ADF) / Total Page Count(FB) (*1)
/ Brake Roller / Pick Roller
0
Remaining Ink (*2)
Power saving
(page 187)
Specify the waiting time before entering power
saving mode.
Range: 5 to 235 min. (in increments of 5) 15 min.
Offset Setting
(page 169)
Adjust the position to start the scan on the selected
scanning side(s).
Unit: Flat bed (*1) / ADF(front) / ADF(back)
Main/Sub: -2 to +2 mm (in increments of 0.5)
Main/Sub: 0 mm
Vertical magnification
Adjustment
(page 169)
Adjust the magnification level in feed direction for
the selected scanning method.
Unit: Flat bed (*1) / ADF
Range: -3.1 to 3.1% (in increments of 0.1)
0%