IBM 22Y Security Camera User Manual


 
Symptom-to-FRU index 135
035-XXX-S99
(Failed RAID test
on PCI slot S. S =
number of failing
PCI slot. Check
System Error Log
before replacing a
FRU.)
1. Adapter
2. SCSI Backplane
3. Cable
035-XXX-SNN
(Check System
Error Log before
replacing a FRU.
S = number of
failing PCI slot; NN
= SCSI ID of failing
fixed disk.)
1. Fixed Disk with SCSI ID NN
on RAID adapter in PCI slot
S.
035-253-S99
(RAID adapter
initialization failure)
1. ServeRAID Adapter in slot S
is not configured properly.
Obtain the basic and extended
configuration status and refer
to the ServeRAID Hardware
Maintenance Manual for more
information.
2. Cable
3. Adapter
075-XXX-000
(Failed Power
Supply test)
1. Power Supply
089-XXX-001
(Failed
Microprocessor
test)
1. Microprocessor
089-XXX-0 02
(Failed Optional
Microprocessor
test)
1. Optional Microprocessor 2
180-XXX-003
(Failed System
Board LED test)
1. System Board
201-XXX-0NN
(Failed Memory
test, see "Memory
Settings" on page
36.) NN = DIMM
location.
1. DIMM Location J1-J4
2. Memory card
201-XXX-999
(Multiple DIMM
failure, see error
text.)
1. See error text for failing
DIMMs
2. Memory card
Error
Code/Symptom