JAI TM-6710 Security Camera User Manual


 
Page 28
Camera Timing Charts
TM-6710/6710CL High-Speed Progressive Scanning CCD Camera
Model: TM-6710/6710CL Operation Mode: 120 Frames/Second
Master Clock: 50.98_HMz, M= 19.62_ nsec
Pixel Clock: 25.49_MHz, P= 39.23_ nsec
3. External Reset Timing
4. Async Reset Timing
External VD
Internal VD
FD
Digital Data
Analog Video
VINIT Trigger
Internal VD
FDV
Digital Data
Analog Video
Horizontal Frequency: 30.49_KHz
1H = 32.8_ µsec Digital
A [254 H], (8.33 msec)
B [0 H], (6 µsec)
C [4.5 H], (147.6 µsec)
D [249.5 H], (8.18 ms)
E [254 H], (8.33 ms)
F [3 H], (98.4 µsec)
I [2 H], (65.6 µsec)
L [3 H], (49.2 µsec)
P [6 H], 98.4 µsec)
G [5 H], (0.164 ms)
J [7 H], (0.23 ms)
M [18 H], (0.295 ms)
N [3 H], (49.2 µsec)
H [249 H], (8.17 ms)
K [242 H], (7.94 ms)
0 [484 H], (7.94 ms)
S [249.5 H], (8.18 ms)
T [254 H], (8.33 ms)
Y [237 H], (7.77 ms)
CC [484 H], (7.94 ms)
Q [1 H], (32.8 µsec)
U [3 H], (98.4 µsec)
AA [18 H] (0.295 ms)
X [7 H], (0.23 ms)
BB [3 H], (49.2 µsec)
DD [6 H], (98.4 µsec)
W [0 H], (3 µsec)
Z Z [3 H], (49.2 µsec)
R [4.5 H]. (147.6 µsec)
V [5 H], (0.164 ms)
Q: Internal VD shift = 1H + async shutter speed
1H = 16.4_ µsec Analog
Q [5 H], (0.164 ms)
H [249 H], (8.17 ms)
Z [5 H], (0.164 ms)
Q [5 H], (164 µsec)
Z [5 H], (0.164 ms)