12. SETUP MENU
MASTER
BLACK
DETAIL
DTL. V/H
BAL
DTL.
FREQUENCY
SKIN DTL
DETECT
V.
RESOLUTION
ADVANCED
PROCESS
PAGE BACK
Item Function, Operation Variation Range Initial Setting
Adjusts the pedestal level (master black), which is the reference of black.
• To increase the pedestal level...... Increase the number. (UP)
• To decrease the pedestal level .... Decrease the number. (DOWN)
Adjusts the detail enhancement level.
• To sharpen details ....................... Increase the number. (UP)
• To soften details ........................... Decrease the number. (DOWN)
Sets the direction, horizontal (H) or vertical (V), in which stronger detail
enhancement is applied.
To strengthen the H enhancement ... ..Increase the number (UP).
To strengthen the V enhancement ... ..Decrease the number (DOWN).
While the LOLUX function is operating, the setting value is fixed at
NORMAL and “FIX” is displayed.
Varies the detail enhancement level by changing the detail enhancement
frequency. Set in accordance with the subject
HIGH ............. Applies strong detail enhancement.
Used to shoot subjects with fine patterns.
MIDDLE ........ Applies medium detail enhancement.
LOW .............. Applies weak detail enhancement.
Used to shoot subjects with large patterns.
While the LOLUX function is operating, the setting value is fixed at
MIDDLE and “FIX” is displayed.
Sets the Skin Detail function to ON or OFF.
ON ................ Skin Detail function activated.
OFF............... Skin Detail function not activated.
See "Using the Skin Detail Function" on page 84.
Increases the vertical resolution.
• NORMAL .... Vertical resolution 380 lines.
• V.MAX ......... Vertical resolution 450 lines
ADVANCED PROCESS
Displays the ADVANCED PROCESS Screen.
See "ADVANCED PROCESS Screen" on page 75.
The CAMERA MENU returns when the SHUTTER dial is pressed with
the cursor at this position.
MAX (100)
99 201
gradations
to
NORMAL (0)
to
-99
MIN (-100)
MAX (9)
816
gradations
to
NORMAL (0)
to
-5
MIN (-6)
H-MAX (4)
39
gradations
to
NORMAL (0)
to
-3
H-MIN (-4)
HIGH
MIDDLE
LOW
ON
OFF
NORMAL
V.MAX
NORMAL
NORMAL
NORMAL
MIDDLE
OFF
NORMAL
12-6 PROCESS Screen
Note:
Note:
Note:
The sensitivity is degraded and the bright sections may be colored
depending on the subject.