Initial Value
–
OFF
–
DOUBLE
WHITE
–
–
OFF
OFF
OFF
OFF
Function & Setting
This sets the title which is displayed permanently at the bottom left of the picture.
This title can be up to 16 characters in length.
☞
P. 30, “CAMERA TITLE Setup”
The 360° panning range can be divided into 16 areas and a title, of up to 16-
character in length, can be set for each area. As the camera is panned manually
these area titles are displayed. This function determines whether area titles are
displayed or not.
ON : Display area titles.
OFF : Do not display area titles.
Sets the area titles.
☞
P. 31, “AREA TITLE Setup”
Sets the size of the characters in the alarm title. (Displayed when an alarm is acti-
vated.)
NORMAL : Same size as the characters used in the menu screen.
DOUBLE : Double the size, both horizontally and vertically, of the characters used
in the menu screen.
Sets the color of the alarm titles.
Setting values: WHITE, YELLOW, CYAN, GREEN
Sets the alarm titles.
☞
P. 32, “ALARM TITLE Setup”
Sets the configuration of the alarm input terminals on the Ceiling Mount.
The picture can be turned black-and-white mode when an alarm signal is input.
☞
P. 25, Item “B&W”
Sets the camera position for alarm 1. When an alarm signal is input to the Alarm 1
input terminal, the camera moves to this set position.
HOME means the home position and POS1 means position 1.
Setting values: OFF, HOME, POS1 to POS99.
Sets the camera position for alarm 2. When an alarm signal is input to the Alarm 2
input terminal, the camera moves to this set position.
HOME means the home position and POS1 means position 1.
Setting values: OFF, HOME, POS1 to POS99.
Sets the camera position for alarm 3. When an alarm signal is input to the Alarm 3
input terminal, the camera moves to this set position.
HOME means the home position and POS1 means position 1.
Setting values: OFF, HOME, POS1 to POS99.
Sets the camera position for alarm 4. When an alarm signal is input to the Alarm 4
input terminal, the camera moves to this set position.
HOME means the home position and POS1 means position 1.
Setting values: OFF, HOME, POS1 to POS99.
CAMERA TITLE/ALARM Screen
This screen sets items related to titles and alarms.
Item
CAM. TITLE EDIT
..
AREA TITLE
AREA TITLE EDIT
..
ALM. TITLE SIZE
ALM. TITLE COLOUR
ALARM TITLE EDIT
..
ALARM INPUT
..
ALARM IN1
ALARM IN2
ALARM IN3
ALARM IN4
● When the item “B&W” is set to ALARM 1 to 4, [B&W] will be displayed at the correspond-
ing ALARM IN 1 to 4 items and the setting cannot be varied.
● When ALARM IN 1 to 4 are set to positions between POS 64 and POS 99, switching to
the preset position does not occur even when an alarm signal is input.