JVC TK-C676 Digital Camera User Manual


 
E-28
Setting Up the Camera Using an RM-P2580
POSITION FUNCTION SET Screen
Item
POSITION TITLE
...
IRIS MODE
BLC
W. BALANCE
R-B GAIN
M-G GAIN
Initial Value
AUTO
OFF
ATW
95
63
Function & Setting
Sets the titles for the 99 preset positions and the home position. Titles can be up to
16 characters in length and are shown in the display.
P. 37, POSITION TITLE Setup
Determines the lens iris adjustment mode.
AUTO : for auto iris adjustment under standard conditions.
AUTO+ : for auto iris adjustment under slightly brighter conditions.
AUTO : for auto iris adjustment under slightly dimmer conditions.
MANUAL : for manual iris adjustment.
Sets of area of back light compensation. Use this function when the object ap-
pears dark (under auto iris control) because of the presence of a bright light source
behind it. This function make it possible to place the unnecessary light source out-
side the photometry area.
Determines the setting of the white balance adjustment. The white balance can be
adjusted for lighting conditions with color temperatures from 2500K to 8000K.
ATW : Auto-Tracking White balance mode, adjusts the white balance automati-
cally according to the color temperature of the lighting conditions.
When ATW is set, --- is displayed for the items R-B GAIN and M-G
GAIN, so that the color phase adjustment cannot be carried out.
AWC : Auto White Control mode, which displays PUSH SET ADJ. STRAT.
When the SET button is pressed, AWC is activated and the white balance
adjustment starts.
If the AWC is activated while the screen is B&W the LOW LIGHT ERROR
will be displayed. This is not abnormal.
Adjusts the phases of R (Red) and B (Blue) under AWC mode.
To enhance blue:Decrease the value.
To enhance red :Increase the value.
Setting values : 0 to 255
Adjusts the phases of M (Magenta) and G (Green) under AWC mode.
To enhance green : Decrease the value.
To enhance magenta : Increase the value.
Setting values : 0 to 255
This screen sets the configurations of functions relating to pictures taken in preset positions.
OFF AREA 1 AREA 2 AREA 3 AREA 4
Photometry area
Photometry area
Photometry area
Photometry area
Photometry area
FACTORY SETTINGS screen
This screen resets values to their factory settings.
Item
FACTORY
SETTINGS
Initial Value
Function & Setting
Resets all settings in the above menus to their initial factory settings. Pressing the
SET button displays EXECUTING (2 sec. approx.) and resets the settings to the
factory settings.
CANCEL : Does not alter current values.
CLEAR (W/O POS. TITLE) : Resets the settings to the initial, factory settings.
However, the set positions, the setting data of each
position and the titles are not reset to the factory set-
tings.
CLEAR (ALL) :
Resets all settings including titles and stored positions.
When the item ExDR MODE (
page 24) is set to ON, the item BLC is set to OFF and
--- is displayed. Under this condition, the settings to the item BLC cannot be varied.
MEMO