JVC VN-C625 Security Camera User Manual


 
102
Operations (Step 5 Operating Using a Web Browser)
Alarm In
For specifying the camera operation upon
input of alarm signals.
1
IN1/IN2
On : Detect Mode
(Set value: Make, Break, Toggle)
: Alarm Out
(Set value: Not Available, OUT1, OUT2)
: Go to a Preset Position
(Set value: Not Available, Home,
Position 1 to Position 99)
: Return Mode
(Set value: Not Available, Return, Event)
: Return Interval
(Set value: 1 to 65535 seconds)
: Black & White
(Set value: Not Available, Color, Black
& White, Auto)
: Message Packet
(Set value: Available, Not Available)
: FTP
(Set value: Available, Not Available)
: Shutdown
(Set value: Available, Not Available)
Off : Do not use Alarm 1 and Alarm 2.
2
Relay Alarm
On : Alarm Out
(Set value: Not Available, OUT1, OUT2)
: Go to a Preset Position
(Set value: Not Available, Home,
Position 1 to Position 99)
: Return Mode
(Set value: Not Available, Return, Event)
: Return Interval
(Set value: 1 to 65535 seconds)
: Black & White
(Set value: Not Available, Color, Black
& White, Auto)
: Message Packet
(Set value: Available, Not Available)
: FTP
(Set value: Available, Not Available)
: Shutdown
(Set value: Available, Not Available)
Off : Do not use Relay Alarm.
Other Triggers
For setting alarm activation via methods other
than alarm input.
3
Preset Position
On : Alarm Output
(Set value: Not Available, OUT1, OUT2)
: Black & White
(Set value: Not Available, Color, Black
& White, Auto)
: Massage Packet
(Set value: Available, Not Available)
Off : Do not use "Preset Position" Alarm.
4
Black & White
On : Alarm Out
(Set value: Not Available, OUT1, OUT2)
: Go to a Preset Position
(Set value: Not Available, Home,
Position 1 to Position 99)
: Return Mode
(Set value: Not Available, Return, Event)
: Return Interval
(Set value: 1 to 65535 seconds)
: Massage Packet
(Set value: Available, Not Available)
Off : Do not use Black & White Alarm.
Alarm Out
For performing setting related to output during
an alarm activation.
5
OUT1/OUT2
On : Output Value
(Set value: ON, OFF)
:Pattern
(Set value: Level, Momentum)
: Momentum Interval
(Set value: 1 to 5000 milliseconds)
Off : Do not output alarm.
5-4 Setting Using the Web Browser (7. Alarm Setting) (Continued)
Notes
Set output settings according to settings of
the device for which alarm output is sent to.
When alarm setting is complete, always
check to ensure that the alarm is functioning
correctly.