JVC VN-C625 Security Camera User Manual


 
17
Alarm Output Terminal
Connect this terminal to alarm devices such
as an annunciator, indicator, lamp or buzzer.
Output Requirements
Equivalent to NPN open collector output (Set
output logic using the controller)
Allowed applied voltage: DC12V and below
Allowed input current: 50 mA
Momentary output: 1 to 5000ms (Set duration
using the controller)
3. Connection of LAN Cables
Use the LAN cable to connect this camera
to a hub or PC
When connecting to a hub
make use of a straight cable.
When connecting to a PC
make use of a cross cable.
IN
R
DC 12 V
GND
VN-C625
OUT
Ter minal
Alarm Device
Connection
Example
(Alarm Output
Equivalent Circuit)
Grounding
Terminal
Note
When using 100 BASE-TX, ensure to use a Category 5 (or higher) cable.
Caution
Connect the grounding terminal of VN-C625
to the GND terminal of the alarm device.
Caution
The use of a cross cable may not be
supported by certain LAN boards on some
rare occasions. As such, please check your
LAN board specifications before connection.
C625_p2-24 05.3.4, 8:07 PM17