Konica Minolta APS Camera Digital Camera User Manual


 
Use higher speed film, increase the brightness, cancel
spot metering.
107106
MODE DISPLAY CAUSE
P
A
S
Spot
ACTION
Shutter speed and
aperture blink
2000, 125, or 30 blinks
Maximum or Minimum
aperture blinks
blinks
LEnS appears
FILM appears
Light level is beyond the range of
available shutter speeds and
apertures.
Required aperture is beyond the
range of the lens.
Light level is below the cameras
minimum metering range.
Lens is not attached, or is
attached improperly.
Film is not loaded.
Required shutter speed is beyond
the range of the camera.
In bright light, attach a neutral density (ND) filter, use film
with lower film speed, or reduce the overall brightness of
your surroundings. In low-light, use flash or another light
source to increase the brightness of your surroundings.
Select a larger/smaller aperture until the display stops
blinking.
Select a faster/slower shutter speed until the display
stops blinking.
Attach the lens, or disconnect and reattach the lens.
If the camera is attached to a microscope or telescope;
contact a Minolta Service Facility for information.
Load film.
Err appears
Camera malfunction
Turn the camera off, then remove and reinsert the
batteries. If normal operation does not resume or the
camera malfunctions repeatedly, contact an authorized
Minolta Service Facility.
PAGE
82-83
20
and blink
Date memory can be lost when
the batteries are changed.
Reset the date and time.
CAMERA WARNINGS
All
All
All
All