Pelco DX9100 Security Camera User Manual


 
68 C634M-D (12/04)
ADVANCED FEATURES
I/O INTERFACE
The DX9200 system can interface with the CM6800, CM9740, or CM9760 matrix switchers. It can integrate with the CM9760-DT,
CM9760-ALM, and CM9760-REL.
CM9760-DT data translator translates the ASCII protocol to the P protocol of the CM9740/CM9760 matrix switchers.
Connect up to four CM9760-ALM alarm units to each DX9200 recorder.
Connect up to four CM9760-REL relay units to each DX9200 recorder.
I/O HANDLER
This application allows the installer to identify one additional external device—the CM9760 data translator, the CM9760-ALM
alarm unit, or the CM9760-REL relay unit—to be connected to the COM port on the recorder. Each of the external devices can
be shared across multiple recorders, but when programming to external devices, the programming only needs to be done on
the recorder which is physically attached to the device.
I/O MANAGER
This application is used in conjunction with the I/O Handler to interface to:
the CM9760-ALM
the CM9760-REL
the CM9760-DT
Since these devices can be shared across multiple recorders across the network, the installer can identify alarm inputs 1-16 for
recorder #1, alarm inputs 17-32 for recorder #2, and so on.