82 C634M-D (12/04)
DATA TRANSLATOR CONFIGURATION
Integrating a data translator serves two functions:
• Synchronize time between the DX9200 system and the matrix switcher.
• Send ASCII command strings to the matrix switcher (CM6800/CM9740/CM9760) for alarm conditions, such as sending
alarms based on motion detection.
NOTE: This programming is required only on the recorder that is physically connected to the CM9760-CC1 or CM6800.
Follow these steps to configure a data translator unit.
1. Go to Start > Programs > DX9000 Server > IO Handler Configuration. The following dialog box appears.
NOTE: You can also open the I/O Handler from the DX9000 Server Configuration Utility.
Figure 107. Data Translator I/O Handler Configuration Dialog Box
2. Click Select Driver on Device 1 (COM 1) or Device 2 (COM 2) to define the external device driver that is connected to the
server. The following dialog box appears.
Figure 108. CM9760 Data Translator Driver Dialog Box
3. Select CM9760DT.dll.