technical notes
Other Flash Units
Use only ash units with one signal terminal, which must
be an X-contact with a positive voltage of no more than
20 V. Use a ash that covers the angle of view of the lens.
1
Close the ash cover (page 2).
2
Attach the ash.
Turn the camera and the optional ash unit o and
attach the ash to the hot shoe.
3
Set aperture manually.
Turn the camera on, select mode A or M, and choose
an aperture (pages 18, 48, 50).
4
Choose a manual ISO sensitivity setting.
Select an option other than Auto for ISO sensitivity
(page 90).
5
Turn the ash on.
Turn the ash on and set it to auto mode. Set
aperture and ISO sensitivity to the values selected
with the camera. Take a test shot and adjust ash
aperture and ISO settings as necessary.
Turn the optional ash unit o before removing it from
the camera.
Cautions
• If the external ash is on, it will re with every shot regardless to
the ash mode selected with the camera. Turn the ash unit o
to shoot without the ash.
• Optional ash units are in principle for use at ranges that exceed
the range of the built-in ash. Using an optional ash unit at
shorter ranges may result in overexposure.