In this chapter, we will check the contents of the package before
installing the SCC-C6475(P), and prepare a power adapter suitable
for the power supply system.
(Power Consumption: 25W; Voltage: AC24V, 1.5A)
Then, we will install the SCC-C6475(P) and connect the cables.
Chapter 2 SCC-C6475(P) Installation
Factory Default
It recovers the whole setting of SCC-C6475(P) to the factory default.
There are two Factory Default methods as follows.
(1) Using the Factory Default in the Reset page
Refer to 5. Setting and changing the function (System - Reset) in
Chapter 3 Network menu Overview.
(2) Using the Factory Default button on the side of the unit.
Proceed as follows.
1. Turn the power off.
2. While pressing the Factory default button, turn the power on.
3. When the Status LED flickers 3 times in red, unpress the Factory
Default button.
4. If the Status LED turns to green, the whole setting of SCC-
C6475(P) recovers to the factory default.
CC
CC
aa
aa
uu
uu
tt
tt
ii
ii
oo
oo
nn
nn
After executing, the user can access only when executing the basic
network setting (IP Address, Subnet<RS-485 Half Duplex
configuration> Mask, Gateway) by using the IP installer.