Appendixes
182
Menu List
04 GAMMA GAMMA OFF/ON ON Turns the gamma correction function on or
off.
STEP GAMMA 0.35 to 0.90 0.45 Sets the master gamma correction curve in
steps.
MASTER GAMMA
(–99 to +99)
0 Sets the master gamma correction curve.
R GAMMA
(–99 to +99)
0 Sets the R gamma correction curve.
G GAMMA
(–99 to +99)
0 Sets the G gamma correction curve.
B GAMMA
(–99 to +99)
0 Sets the B gamma correction curve.
TEST OUT SELECT ENC/R/G/B ENC Selects the output signal of TEST OUT
connector.
GAMMA SELECT STD/FILM STD Selects the gamma table.
GAMMA SEL (STD) 1 to 6 3 Selects the gamma table of STD.
GAMMA SEL (FILM) 1 to 5 1 Selects the gamma table of FILM.
05 BLK GAMMA BLACK GAMMA OFF/ON OFF Turns the black gamma correction on or off.
BLK GAMMA RANGE LOW/L.MID/
H.MID/HIGH
HIGH Sets the range affected by black gamma.
MASTER BLK
GAMMA
(–99 to +99)
0 Adjusts the master black gamma.
R BLACK GAMMA
(–99 to +99)
0 Sets the correction curve of the R black
gamma.
G BLACK GAMMA
(–99 to +99)
0 Sets the correction curve of the G black
gamma.
B BLACK GAMMA
(–99 to +99)
0 Sets the correction curve of the B black
gamma.
TEST OUT SELECT ENC/R/G/B ENC Selects the output signal of TEST OUT
connector.
06 KNEE KNEE OFF/ON ON Turns the knee correction circuit on or off.
KNEE POINT 50 to 109% 85.0 Sets the knee point level.
KNEE SLOPE
(–99 to +99)
0 Set the knee slope level.
KNEE SATURATION OFF/ON ON Turns the knee saturation function on or off.
KNEE SAT LEVEL
(–99 to +99)
0 Sets the knee saturation level.
WHITE CLIP OFF/ON ON Turns the white clipping function on or off.
WHITE CLIP LEVEL 100.0 to 109.5% 109.0 Adjusts the white clipping level.
07 DETAIL 1 DETAIL OFF/ON ON Sets the detail correction function on or off.
APERTURE OFF/ON ON Turns the aperture correction function on or
off.
DETAIL LEVEL
(–99 to +99)
0 Sets the general level of the detail signal.
APERTURE LVL
(–99 to +99)
0 Sets the aperture level.
DTL H/V RATIO
(–99 to +99)
0 Sets the level of the V detail signal.
CRISPENING
(–99 to +99)
0 Sets the crispening level.
LEVEL DEPEND OFF/ON ON Turns the level depend function on or off.
LV. DEPEND LVL
(–99 to +99)
0 Sets the level of the level depend.
DETAIL FREQ.
(–99 to +99)
0 Sets the frequency of the H detail signal.
No. Page Item Settings Default Description