Speco Technologies & IP-WDRB1 Security Camera User Manual


 
126
IP Camera Users Manual Speco Technologies
Check with ‘C-1-2 Network Cable (LAN cable) and cable connection check’.
PING Test
In case Camera uses Static/Public IP: input “Ping IP address” to
command window
of PC and check response.
In case camera uses dynamic/public IP: In this case, user cannot find camera IP
address. So, reset hardware and connect PC with THE CAMERA through cross cable
and ping test by “192.168.1.7”.
In case camera uses private IP through IP sharing device:
Ping-test private IP
address set for THE CAMERA in PC that is connected in the local network through IP
sharing device.
If “ping test” get response, network setting for camera is done correctly.
If ping test is okay but there is no connection
, check with ‘C-2-2 check port setting’..
C-2-2. Check Port Setting
If user can’t connect with camera even though ‘Ping test’ is okay, please check port
setting by the following steps.
THE CAMERA uses 3 ports as follow.
Web Connection Port : Port 80 TCP
Authentication and Control Port : Port 9000 TCP
Video Streaming Port : Port 9001 TCP
Motion Detection Control Port : Port 9005 TCP
If it is not available even to connect to web, check web connect port because web
connect port may be set with other number than ‘80’.
In case there is problem in video monitoring even though there is no problem in Web
connection, check if ‘Authentication and Control Port’ and ‘Video Streaming Port’ of THE
CAMERA is set on IP sharing device (in case of using IP sharing device).
For setting of IP sharing device Port, refer to ‘IP sharing device Setting’.
C-3 In case web page can’t be connected under ultrahigh speed internet line
Some ultrahigh ISP company may block not to use Web port number 80. In this case,
change to other number from web connection port setting.