Bosch Appliances VIP X1600 M4S Security Camera User Manual


 
104 en | Appendix VIP X1600 M4S
DOC | V4.0 | 2009.06 Installation and Operating Manual Bosch Security Systems
8.2 General Malfunctions
Malfunction Possible causes Recommended solution
No connection between
module and terminal
program.
Incorrect cable connections. Check all cables, plugs,
contacts, terminals and
connections.
The computer's serial interface
is not connected.
Check the other serial interface.
Interface parameters do not
match.
If necessary select a different
interface and make sure that the
computer's interface parameters
match those of the module. Try
the following standard
parameters: 19,200 baud, 8 data
bits, no parity, 1 stop bit. Next,
disconnect the unit from the
power supply and reconnect it
again after a few seconds.
No image on the monitor. Monitor error. Connect local camera or other
video source to the monitor and
check the monitor function.
Faulty cable connections. Check all cables, plugs, contacts
and connections.
No connection
established, no image
transmission.
The module's configuration. Check all configuration
parameters.
Faulty installation. Check all cables, plugs, contacts
and connections.
Wrong IP address. Check the IP addresses
(terminal program).
Faulty data transmission within
the LAN.
Check the data transmission
with ping.
The maximum number of
connections has been reached.
Wait until there is a free
connection and then call the
sender again.
No audio transmission to
remote station.
Hardware fault. Check that all connected audio
units are operating correctly.
Faulty cable connections. Check all cables, plugs, contacts
and connections.
Incorrect configuration. Check the audio parameters on
the Audio configuration page.
The audio voice connection is
already in use by another
receiver.
Wait until the connection is free
and then call the sender again.