5.39 Advanced Mode: Switch Configuration
The parameters on this page can be used to configure the switch integrated into VIP X1600 XF
and adapt it to the network. If several Ethernet interfaces of the VIP X1600 XF are connected
with the network, you can use different protocols to optimize data transfer. Detailed
knowledge of the network in which the VIP X1600 XF is located is essential in order to
configure the parameters on this page.
Operating mode
Select the required operating mode for the switch. The operating mode is used to determine
the communication protocol.
Static port trunking enables increased data transfer by bundling Ethernet interfaces.
Through a process of continuous checking, the RSTP (Rapid Spanning Tree Protocol)
determines the fastest possible route for data packets in the network. Other parameters are
used to define detailed settings.
i
NOTICE!
The parameters for switch configuration can only be changed for the module in Slot 1. This