8.5 Processor Load
If the VIP X1600 M4S encoder module is accessed via the Web browser, you will see both of
the processor load indicators in the top left of the window next to the manufacturer's logo.
Moving the mouse cursor over the graphic indicator displays the status of the processor
together with the numerical values. This information may help you with troubleshooting or
fine tuning the unit.
8.6 Network Connection
You can display information about the network connection. To do this, move the cursor over
the i icon.
8.7 Serial interface
Options for using the serial interface include transferring transparent data, controlling
connected units or operating the unit with a terminal program.
The serial interface supports the RS-232/RS-422/RS-485 transmission standards. The mode
used depends on the current configuration (see Section 5.36 Advanced Mode: COM1, page 72).
Connection is via the terminal block.
8.8 Terminal Block
The terminal block has several contacts for:
4 alarm inputs
4 relay outputs
Serial data transmission
Pin Assignment
The pin assignment of the serial interface depends on the interface mode used (see
Section 5.36 Advanced Mode: COM1, page 72).
Link Ethernet link type
UL Uplink, speed of the outgoing data traffic
DL Downlink, speed of the incoming data traffic
Contact RS232 mode RS422 mode RS485 mode
CTS CTS (clear to send) RxD- (receive data minus) Data-
TXD TxD (transmit data) TxD- (transmit data minus)
RXD RxD (receive data) RxD+ (receive data plus) Data+
RTS RTS (ready to send) TxD+ (transmit data plus)
GND GND (ground)