VIP X1600 M4S Installation | en 21
Bosch Security Systems Installation and Operating Manual DOC | V4.0 | 2009.06
Relay Outputs
The module has four relay outputs for switching external units such as lamps or alarm sirens.
You can operate these relay outputs manually while there is an active connection to the
module. The outputs can also be configured to automatically activate sirens or other alarm
units in response to an alarm signal. The relay outputs are also located on the orange terminal
block (see Section 8.8 Terminal Block, page 107).
X Connect the lines to the appropriate terminals on the orange terminal block (R1 to R4)
and check that the connections are secure.
4.4 Setup Using the Configuration Manager
The Configuration Manager program can be found on the product CD contained in the
VIP X1600 XF base's scope of delivery. This program allows you to implement and set up new
modules quickly and conveniently.
Installing the Program
1. Insert the CD into the computer's CD-ROM drive.
2. If the CD does not start automatically, open the Configuration Manager directory using
Windows Explorer and double-click Setup.exe.
3. Follow the on-screen instructions.
!
CAUTION!
A maximum load of 30 V and 2 A may be applied to the relay contacts.
i
NOTICE!
Using the Configuration Manager to set all parameters in the module is an alternative to
configuration by means of a Web browser, as described in chapter 5 of this manual.