7-10
7.2 Setup mode functions
LCD
display
Descriptions Selectable
parameters
Default Mode Remarks
On-
line
Off-
line
Abrasion
Alarm
Specifies the scanners
operation when consumables
replacement occurs: stop
scanning or message display
only. Also specifies the
consumable replacement
message timing.
Stop/Message
10,000 to
2,560,000 sheets
Stop
300,000
Avail-
able
Avail-
able
The
replacement
timing
increment/
decrement by
10,000 sheets.
Abrasion
Counter
Clear the consumable counters
(Abrasion counter)
--Not
Avail-
able
Avail-
able
-
Manual Feed Specifies the pick start time
from the time document is
manually set.
0.2 to 29.8 sec 1.0 sec Avail-
able
Avail-
able
-
Specifies the waiting time from
the execution of read command
on PC to document insertion.
1, 5, 10, 20, 30,
40, 50, 60, 70, 80,
90, 100, 110, 120,
180, 240, 255 sec
30 sec