7-14
7.2 Setup mode functions
LCD
display
Descriptions Selectable
parameters
Default Mode Remarks
On-
line
Off-
line
Baud Rate Specifies the control data
transfer rate for TPS interface.
19200/
9600/
4800/
2400
9600 Not
Avail-
able
Avail-
able
New setting
valid after
power cycle.
Imprinter When both fi-486PRFR (Pre-
imprinter) and fi-486PRRE
(Post-imprinter) are installed,
specifies which one to setup.
Pre / Post - Avail-
able
Avail-
able
-
Numbering When either fi-486PRFR (Pre-
imprinter) and fi-486PRRE
(Post-imprinter) is installed,
set the numbering parameters.
Numbering
: On / Off
Numberin
g
: Off
Avail-
able
Avail-
able
Settings via the
PC have the
priority.
Digits
: 5 / 8
Digits
: 5
Initial No.:
5digit:0-99999
8digit:
0-16777215
Initial No.:
00000
Reset at hopper
empty: On/Off
Reset at
hopper
empty: On
Ink Shows the remaining ink.
Reset remaining ink amount
counter when the Print
cartridge is replaced.
--Avail-
able
Avail-
able
-