showenvironment(8)
System Administration 283
NAME showenvironment - display the intake air temperature and humidity, temperature
sensor information, voltage sensor information, and fan rotation information about
the system
SYNOPSIS showenvironment [-M][type]
showenvironment -h
DESCRIPTION showenvironment(8) command displays the information listed below.
The following types of the information are displayed:
Privileges You must have one of the following privileges to run this command:
useradm, platadm, platop, fieldeng
Refer to setprivileges(8) for more information.
OPTIONS The following options are supported:
OPERANDS The following operand is supported:
Environment
information
Intake temperature and humidity of the system (humidity only
for high-end server)
Temperature
information
Intake temperature of the system and exhaust temperature of
each component
Voltage
information
Voltage sensor value
Fan rotation
information
Fan rotational state and revolutions per unit of time
-h Displays usage statement. When used with other options or
operands, an error occurs.
-M Displays text by page. This option provides a function that is
the same as that of the more command.
type Specifies the one of the type of information to be displayed. The
following types can be specified. If this type setting is omitted,
intake temperature and humidity information about the system
is displayed:
temp Displays temperature information.
volt Displays voltage information.
Fan Displays fan rotation information.