CONNECTION OF A REMOTE CONTROLLER (RCU AND A COAXIAL MULTIPLEX SYSTEM)
The optional multiplex adaptor WV-PS550 is used for
connection of a coaxial multiplex system.
1. Turn RCU power off before connecting cables.
2. Connect the optional multiplex adaptor WV-PS550 to
the control connector of the camera through the stan-
dard accessory cable supplied with the WV-PS550.
3. Set the cable selection switch of the RCU to VP.
4. Connect the MPX connector of the multiplex adaptor
and that of the RCU with a coaxial cable (Belden 8281
or equivalent).
5. Turn RCU power on and the power indicator lamp will
light. The camera can now be remote controlled by
the RCU.
NOTES:
Use only model WV-RC700A (with WV-CB700A) as an
RCU.
A coaxial multiplex system cannot be used with a stu-
dio 26-pin cable.
R/G/B, Y/C and Y/PR/PB signals cannot be transmitted
through this system. Use a studio cable if any of
these signals is required.
The maximum cable extension length allowed for this
system is 300 meters.
GEN-LOCK
IN
AUX
IN
AUTO
75/Hi-Z
AUTO
75/Hi-Z
R/PR /C
OUT OUT
AUDIO
SEE MANUAL
VIDEO 1
G/Y/Y VIDEO 2
B/PB /B SYNC
S-VIDEO
14
23
TALLY
CAMERA (MULTI)
CABLE SELECT
FUSE
125V 2A
TALK
INCOM
RECEIVE
CONTROL
TALLY & INCOM
MULTI OVP
MPX
MPX
OUTPUT
ZOOM/FOCUS
REMOTE
EXT DC IN
PAGE
ITEM
(AWC)
UP
(ABC)
DOWN
(BAR)
IRIS
SEE MANUAL
CAUTION
CONNECT TO SPECIFIED
CLASS 2 POWER SUPPLY
ONLY SEE MANUAL
VBS/HD
75
VD
VIDEO/RGB
CONTROL
VIDEO OUTG/L IN
ON
OFF
AUDIO
CONTROL OUTCAMERA
MPX DATA IN AUDIO IN
DATA
Supplied with
WV-PS550
multiplex adaptor WV-PS550
Set to VP
WV-RC700A
Coaxial cable
(Belden 8281 or equivalent)