-37-
■ Initial Set State
(1) Display the SETUP menu by pressing the page button.
(2) Move the cursor to INIT and press the page switch.
The camera is initialized and the INITIAL set menu is
displayed on the monitor. Setup operation can be per-
formed at the camera head or RCU (RCB).
■ Initial Set Screen
<Camera Alone> <Camera with
RCU (RCB)>
NO.1 ** INITIAL **
R GAIN (+....I....-)
B GAIN (+....I....-)
T PED (+....I....-)
R PED (+....I....-)
B PED (+....I....-)
PAINTING OFF
RET
NO.2 ** INITIAL **
AGC AUTO IRIS ELC
LEVEL +....I....-
AREA ALL
PEAK/AVG P....I....A
AUTO IRIS ADJ OFF
RET
On No. 2 page, the light adjusting function that is now
ON is displayed on the second line from the top.
* When the camera is used with an RCU (RCB), those
items enclosed in parentheses can be adjusted with
the switches and controls on the RCU (RCB).
The word END is displayed only when the camera is
used alone.
NO.1 ** INITIAL **
R GAIN +....I....-
B GAIN +....I....-
T PED +....I....-
R PED +....I....-
B PED +....I....-
PAINTING OFF
RET END
NO.2 ** INITIAL **
AGC AUTO IRIS
LEVEL +....I....-
AREA ALL
PEAK/AVG P....I....A
AUTO IRIS ADJ OFF
RET END