Panasonic WV-NP502/WV-NW502S Security Camera User Manual


 
62
Configure the settings relating to Panasonic alarm protocol [Notification]
Click the [Notification] tab on the "Alarm" page. ( pages 20 and 21: How to display/operate the setup menu)
The settings relating to Panasonic alarm protocol can be configured in this section.
Panasonic alarm protocol notification
[Panasonic alarm protocol]
Select "On" or "Off" to determine whether or not to pro-
vide notification by Panasonic alarm protocol according
to the settings for the "Alarm" and "Diag." checkboxes of
"Destination of notification" below.
When an alarm is detected ("Alarm")
When a notification of the remaining capacity of the
SD memory card has been provided ("Diag.")
When the SD memory card has become full ("Diag.")
When the SD memory card cannot be recognized
("Diag.")
Default: Off
Note:
When "On" is selected, notification of the alarm
occurrence will be provided to the registered desti-
nation addresses in order (to IP address 1 first, to IP
address 8 last).
[Destination port]
Select a destination port for the Panasonic alarm proto-
col from the following.
Available range: 1 - 65 535
Default: 1 818
[Retry times]
Select a retry time for the Panasonic alarm protocol.
Available range: 0 - 30
Default: 2
Destination of notification
[Address 1] - [Address 8]
Enter the destination IP address of the Panasonic alarm
protocol from the following. Host name is unavailable for
the IP address. Up to 8 destination addresses can be
registered.
"Alarm" checkbox: When the checkbox is checked,
the Panasonic alarm notification will be provided
upon an alarm occurrence.
"Diag." checkbox: When the checkbox is checked,
notification using Panasonic alarm protocol will be
provided in the following cases.
When notification of the remaining capacity of
the SD memory card has been provided
When the SD memory card has become full
The SD memory card cannot be recognized
"Destination IP address": Enter the destination
address.
To delete the registered IP address, click the [Delete]
button respective to the desired IP address.
Important:
Confirm that the destination IP addresses are regis-
tered correctly. When a registered destination does
not exist, notification may be delayed.