Samsung SNB-7000 Security Camera User Manual


 
English _63
SETUP SCREEN
Specify the record conditions.
Record profile : Display the number of profile to record.
Record 1 fps forcibly : Only one frame per second will be recorded regardless of
the existing record profile.
For H.264, it will be enabled only if the bit rate is less than 4800.
For MJPEG, it will be enabled only if the resolution is less than 800x600.
Overwrite : If the SD memory is full, this will delete old data and store new data in
replacement.
Pre-alarm duration : Specify the time point before the occurrence of the alarm;
starting from the time point, the images will be transferred. You can specify up to
5 seconds before the occurrence of the alarm.
Post-alarm duration : Specify the time point after the occurrence of the alarm; to
the specified time point, the images will be transferred. You can specify up to 120
seconds after the occurrence of the alarm.
When done, click [Apply (
)].
Alarm input
You can set the alarm input type, activation time, and operation mode.
From the Setup menu, select the
<Event (
)> tab.
Click <Alarm input>.
Specify an input device.
Type
Normal Open : It is normally open,
but if it is closed, an alarm will be
triggered.
Normal Close : It is normally
closed, but if it is open, an alarm
will be triggered.
Specify the <Activation time>.
Always : Always check if an alarm occurs. It activates in operated mode when the
alarm occurs.
If set to Always, the activation time cannot be changed.
Only scheduled time : Check if an alarm occurs at a specified day of the week for
a specified time period. It activates in operated mode when the alarm occurs.
[
] : Reset all settings.
3.
-
-
4.
1.
2.
3.
-
-
4.