Alarm Settings (ALARM)
39
The ALARM IN screen allows you to perform the alarm settings
(input preferences, alarm action, etc.) for each alarm input
number.
1
Use the joystick lever (xy) to select [ALARM IN],
use the lever (vw) to select an alarm input number
(1 - 8), and press the [ENTER] button.
The ALARM IN screen appears.
2
Use the joystick lever (xy) to select [POLARITY]
and use the lever (vw) to select the polarity for the
alarm input signal.
Available settings:
• NO (Normal Open):
Normally open so closed condition is detected as input.
• NC (Normal Close):
Normally closed so open condition is detected as input.
3
Use the joystick lever (xy) to select [ACTION] and
use the lever (vw) to select the action after the
alarm is detected (alarm action).
Available settings:
•PRESET: When the alarm is detected, the camera
moves to the preset position whose preset
number is the same as the alarm input
number.
• SEQ A - D: Starts the Sequence mode operation (A - D).
• PAN 1 - 4: Starts the Auto Pan mode operation (1 - 4).
• TOUR 1 - 4: Starts the Tour mode operation (1 - 4).
•OFF: Does not perform the alarm action.
4
Use the joystick lever (xy) to select [RETURN] and
use the lever (vw) to select the operation after the
alarm action.
Available settings:
•OFF: Does not return to the operation status before the
alarm.
•ON: Returns to the operation status before the alarm.
Memo: • When [RETURN] is set to “ON”, the camera returns to the
before-alarm status after the duration specified in the
[DURATION] setting.
• If another alarm input is received during the time specified
in the [DURATION] setting, the operation will be performed
according to the last alarm.
5
Use the joystick lever (xy) to select [MOTION
ALARM] and use the lever (vw) to select how the
motion sensor is used.
For alarm detection criteria, the motion sensor built into the
camera can be used in combination with the alarm input from
an external device.
Available settings:
• AND: When both the motion sensor and the external
device detect an alarm condition, the alarm is
activated.
•OR: When either the motion sensor or the external
device detects an alarm condition, the alarm is
activated.
6
Use the joystick lever (xy) to select [ALARM OUT]
and use the lever (vw) to select an alarm output
terminal.
The alarm signal can be output from the alarm output terminal,
enabling you to connect external devices such as recorder,
alarm buzzer and warning lamp.
Available settings:
•OFF: Does not output the alarm signal.
•1: Uses the output terminal 1.
•2: Uses the output terminal 2.
7
Use the joystick lever (xy) to select [LINE OUT] and
use the lever (vw) to determine whether the alarm
signal is output to the connection line to the
system controller.
Available settings:
•OFF: Does not output the alarm signal to the connection
line.
•ON: Outputs the alarm signal to the connection line.
A Setting the alarm input (ALARM IN)
Before using the “PRESET” option, set the preset
position for the corresponding alarm input number.
ALARM
ALARM IN y
ALARM OUT y
ALARM DISABLE
MOTION
ALARM DISPLAY
PRESET
MENU
1
1
OFF
OFF
OFF
OFF
BACK
ALARM IN 1
POLARITY
ACTION
RETURN
MOTION ALARM
ALARM OUT
LINE OUT
DURATION
NO
PRESET
ON
OR
OFF
OFF
5S
Before enabling the settings under [MOTION], be
sure to set [MOTION] in the ALARM screen to
“PRESET”.