Sanyo VCC-MC700P Security Camera User Manual


 
8
Camera Settings (CAMERA)
Adjusts vertical synchronization signal for the camera.
Internal synchronization (INT)
Power source synchronization (L-L)
Sets lens aperture according to the luminance level of the target
object.
Auto iris (AUTO)
Manual iris (MANU)
Sets the white balance according to the shooting conditions.
Auto trace white balance (ATW)
One-push automatic white balance (AWC)
Fixed white balance (3200/5600/FLUO)
Manual white balance (MWB)
Sets the backlight compensation function to get clearer image in
backlight condition.
Multi-spot evaluative metering (MULT)
Center-weighted average metering (CENT)
Multi-spot metering (MASK)
•OFF
Sets the appropriate shutter speed according to your surveillance
purpose.
Fast shutter speed (SHORT)
Slow shutter speed (LONG)
•OFF
Adjusts the profile of the target object horizontally or vertically.
•ON y
•OFF
CAMERA y
LENS y
PAN/TILT y
AUTO MODE y
ALARM y
PRIVACY MASK y
PASSWORD y
LANGUAGE y
OPTION y
PRESET
MENU
SYNC
IRIS y
WHITE BALANCE y
BLC
SHUTTER
APERTURE y
AGC y
GAMMA
DAY/NIGHT y
PRESET
MENU
A
B
F
E
D
C
SET
SET
SET
SET
SET
SET
SET
SET
SET
OFF
BACK
INT
AUTO
ATW
OFF
OFF
ON
ON
0.45
AUTO
OFF
BACK
A
Adjusting synchronization signal (SYNC)
B
Setting lens aperture (IRIS)
C
Setting the white balance (WHITE BALANCE)
L-L SETTING
[V SYNC PHASE]
141
+
P10
IRIS SETTING
SENSE UP
[LEVEL]
40
+
OFF
P11
ATW SETTING
MASKING
---
P12
D
Setting the backlight compensation level
(BLC)
The multi-spot metering (MASK) function is available
only when registering a view setting file in the CAMERA
VIEW screen (P27).
E
Setting the electronic shutter (SHUTTER)
F
Setting the profile compensation (APERTURE)
7
BLC SETTING
[BLC WEIGHT]
[BRIGHT]
7
P14
ES SETTING
SHUTTER SPEED
50
P16
APERTURE SETTING
H 8
V 8
P17