Sanyo VCC-WB4000P Security Camera User Manual


 
Alarm Settings
B Detecting Intruders Using Motion
Detector Settings
You can set sensor marks in the live image
screen to detect intruders.
When an alarm is detected, an alarm buzzer can
be made to sound and the ALARM indicator on
the live image screen can be made to illuminate.
1
Set ALARM REC USE to NO USE
(example), and then click the [SET] button.
Set to NO USE first so that alarms cannot
be detected while you are making the
settings. Change the setting back to USE
after you have finished making the settings.
2
Set EXTERNAL ALARM to OFF
(example).
3
Set MOTION DETECTOR to ON.
The motion detector level and MOTION
DETECTOR SET screen will be displayed.
Available settings:
OFF: Motion detector operation is not
carried out.
ON: The MOTION DETECTOR SET
screen is displayed.
4
Use the drop-down list box to change the
MOTION DETECTOR LEVEL setting
(example: 2).
The smaller the value selected, the higher
the sensitivity.
Available settings: 1 to 10 (default setting: 5)
5
Set the sensor marks.
These correspond to the live image screen
and the sensing area.
Move the pointer to the same position (grid area)
as the area of the live image screen that you
would like sensing to be carried out, and then
click the mouse button.
A sensor mark (ú) will be displayed. Click in the
same place once more to clear the mark.
In the same way, insert sensor marks in other
places as required.
After setting the sensor marks, the sensor
sensitivity can be adjusted. (p. 41)
6
Set ALARM OUT to NO (example).
Available settings:
OFF: No alarm is output when an alarm is
received.
NC: Normal close (normally closed, but
an alarm is output when open).
NO: Normal open (normally open, but an
alarm is output when closed).
Note: If ALARM OUT has been set to NO
or NC for the COLOR mode or
TIMER mode DAY/NIGHT settings
and an IR lamp has been connected,
then the buzzer will not sound. (p. 32,
34)
7
Set ALARM OUT MODE to ALARM
OUT.
8
Use the drop-down list box to change the
ALARM OUT TIME setting to 60 sec.
(example).
Available settings:
2, 5, 10, 15, 20, 30, 60 sec.,
2, 3, 4, 5 min., REMOTE
(The REMOTE setting only appears
when ALARM OUT MODE is set to
REMOTE CONTROL.)
1
2
3
4
5
6
7
8
L5AM2/XE (VCC-WB4000P) GB 2004, 2, 17
40
English