Sennheiser 100-P SERIES Camcorder User Manual


 
Product overviews
9
Overview of the displays of the SK 100/SKM 100/SKP 100 G3
After switch-on, the transmitter displays the standard display “Frequency/Name”.
For further illustrations and examples of the different standard displays, refer to page 22.
The display backlighting is automatically reduced after approx. 20 seconds.
Display Meaning
Audio level “AF Modulation of the SK/SKM/SKP 100 G3
with peak hold function.
Frequency Current transmission frequency
Name Freely selectable name of the transmitter
Transmission icon RF signal is being transmitted
Lock mode icon Lock mode is activated
Pilot tone “P Pilot tone transmission is activated
MUTE Audio signal is muted
Battery status Charge status:
MHz
533.875
ew100 G3
MUTE
P
AF
approx. 100%
approx. 70%
approx. 30%
Charge status is critical, the red
LOW BATTERY LED /¿/¾ is flashing:
¿
P
¾
ew 100 P G3 Set _529660_0309_Sp9.book Seite 9 Mittwoch, 8. April 2009 6:57 18