Chapter 9 Maintenance
Voltage Low
WARNING indicator Warning sound Tally/REC Battery remaining
Problem Operation in the recorder
module
Action to take
The DC IN voltage has
become low (stage 1).
Recording continues. Check the power supply.
Insufficient Voltage
WARNING indicator Warning sound Tally/REC Battery remaining
Problem Operation in the recorder
module
Action to take
The DC IN voltage is
too low (stage 2).
Recording cannot be
performed.
Recording stops. Connect other power source.
Battery Error
Please Change Battery.
WARNING indicator Warning sound Tally/REC Battery remaining
——
Problem Operation in the recorder
module
Action to take
An error was detected
with the battery pack.
Recording stops. Replace the battery pack with a normal one.
Backup Battery End
Please Change.
WARNING indicator Warning sound Tally/REC Battery remaining
——
Problem Operation in the recorder
module
Action to take
The remaining power
of the backup battery
is insufficient.
Recording continues. Refer to a Sony service representative to replace
the battery with a new one.
Unknown Media(A)
1)
Please Change.
WARNING indicator Warning sound Tally/REC Battery remaining
——
Problem Operation in the recorder
module
Action to take
A partitioned memory
card or one that
contains recorded clips
exceeding the number
permitted with this
camcorder is loaded.
Recording continues. This card cannot be used with this camcorder.
Remove it and load a compatible card.