6.5.1 Setting the address (ID) of the camera
To prevent faulty operations and malfunctions, each camera
must have an unique address (ID). The default setting is
0[ID001].
Table 6.5 Dome Camera ID Setting (Rotary Switches SW301, SW302)
6.5.2 Setting the protocol of the camera
Set the protocol setting, the baud rate, and the termination
setting of dip switch SW303, using the data in the tables below.
Note: The value marked * is the default setting.
Table 6.6 Camera Protocol Setting (No. 1 & 2, Dip Switch SW303)
Table 6.7 Camera Baud Rate Setting (No. 3 & 4, Dip Switch SW303)
Table 6.8 Camera’s RS-485 Termination Setting (No. 5, Dip Switch
SW303)
X0 X1
SW301 SW302
No1 No2 Protocol
Off On Bosch OSRD*
Off Off Pelco-D/Pelco-P
No3 No4 Baud Rate (bps)
Off Off 2400
Off On 4800
On Off 9600*
On On 38400
No5 Termination
Off Off
On On*
NOTICE!
When the RS-485 signal is looped through, make sure that
(only) the last device is properly terminated. Improper RS-485
wiring or termination may result in unreliable system operation.