6633
6622
Advanced recording
A calibration error may occur under extremely bright light
sources, especially with flash units. If an error occurs, a
message appears on the monitor and the white-balance
indicator is yellow. Highlight the return button and press the
center of the controller. Recalibrate using a gray card as a
reference target to reduce the intensity of the illumination.
White balance can be set to a known color temperature of a
light source or set to the color temperature determined by a
color meter.
With the white balance dial in the K position, press the white-
balance button to open the setting screen.
The front control dial or the left/right controller keys adjust the
color temperature in thousands of degrees. The rear control
dial or the up/down controller keys adjust the color
temperature in hundreds of degrees.
Press the central controller button to complete the operation.
For information on light sources, see page 81.
Color Temperature
CCoolloorr tteemmppeerraattuurree
::aaddjjuusstt ::eenntteerr
Color temperature refers to the color of the light emitted from a blackbody radiator at a specif-
ic temperature given in degrees Kelvin. This is an accurate way of measuring light from contin-
uous-spectrum sources such as the sun and incandescent or tungsten light bulbs. However,
color temperature can be inaccurate with discontinuous-spectrum sources such as fluorescent
and mercury vapor.
About Color Temperature
MEMORY - STORING CAMERA SETTINGS
To save the current camera settings, press
the M SET button (1); the setting appear on
the registration screen.
Use the control dials or left/right keys of
the controller to select the memory register
in which to store the settings; any previous
settings are replaced. Press the central
controller button to complete the
operation.
Three sets of camera settings can be saved. This saves time under frequently repeating conditions
by eliminating the need to set the camera. Camera settings cannot be deleted from memory by
turning the camera off. They are erased with the reset function in section 3 of the setup menu.
SSeelleecctt rreeggiisstteerr
::aaddjjuusstt ::eenntteerr
MMeemmoorryy rreeggiisstteerrss
Camera settings are recalled with the
exposure-mode dial.
Press the Dial Lock Release and turn the
exposure mode dial to the appropriate
memory register (2).
The camera settings are displayed on the
monitor. The dial positions may not reflect
the camera settings.
The M SET button can be used as a menu
short cut. The shortcut function is set in
section 4 of the custom menu.
Memory register
SSeelleecctt rreeggiisstteerr
::sseelleecctt ::eenntteerr
Return button
CCuussttoomm WWBB eerrrroorr..