Exposure
The viewfinder shows the focused area (depth of field) with the selected aperture value.
Press the (Preview) button to use the preview
function.
There are 5 ways to measure the subject brightness: Digital ESP metering, Center weighted
averaging metering, and 3 types of spot metering. Select the most suitable mode for the
shooting conditions.
Setting display
G Digital ESP metering
During live view, the camera measures the light levels and calculates the light level differences in
324 separate areas of the image (49 areas when shooting with the view finder). This mode is
recommended for general use.
Setting the AF synchronized function to [ESP+AF] enables metering centered around the AF target
that is in focus with AF. It is available when shooting using the view finder (phase difference AF).
Preview function
Changing the metering mode
Direct button G + k
Super control panel ip: [METERING]
Menu MENU[c][V]
[METERING]
G : Digital ESP metering
H : Center weighted averaging metering
I : Spot metering
IJ: Spot metering - highlight control
IK : Spot metering - shadow control
Viewfinder
Control panel
(Preview) button
i button
G button
MENU button
k