Broadband Router User Guide
20
The period of time between each email being sent to the receiver. If the setting is at
10 seconds, a new e-mail will be sent in 10 seconds interval to the receiver.
Sending Time
The number of times the e-mail will be sent to the receiver before it terminates.
Select “Trigger I/O Output” and enter the setting for Output 1 time and Output 2 time
in seconds. These fields determine the duration for activating the external output
devices.
I/O Input 2 Trigger setting procedures are same as above.
Save/Cancel:
After making sure all settings in the System are correct, click on the “Save” icon to
store the settings for ICA-100 series. You can alternatively click on the “Cancel” icon
to restore all settings to the values last saved to or retrieved from ICA-100 series.
Please refer to the appendix for detailed information regarding the I/O Connector.
Warning
When connecting other devices through the I/O connectors, please make sure the
maximum current of 100mA is strictly observed. Any failure to do so might cause a
loss of power to ICA-100 series and possibly cause serious damage to ICA-100 series.
Upload
The Upload menu contains commands for setting ICA-100 series to upload images to
a specified FTP server, time scheduling, and manual operation. Click on “Upload” in
the system administration menu bar and the Upload screen will appear as illustrated
below:
Note: Before using the Upload function, please ensure the User account used has
“write” permission of the FTP server or the specified folder.