<2> [Target Setting] area
In this area, ESF files can be created and selected, and PR5 files and program files can be selected. A warning message
will be displayed in the [Information] area if there is a mismatch between PR5 files, ESF files and program files saved
in the FP5 and information held in the programming GUI. Information of PR5 files, ESF files and program files, which
is set to the current valid programming area, can be deleted.
Figure 1.49 [Target Setting] Area
<3> [Parameter and Setting file] area
In this area, ESF files can be created and selected, and PR5 files can be selected.
Figure 1.50 [Parameter and Setting file] Area
ESF file selection list box
Select the ESF file to be used. If no ESF files are registered in the valid programming area, ESF files stored in the
FP5_PRJ folder in the programming GUI installation folder are displayed. If the reference folder is changed by using
the ..., New... or Save As... button, ESF files stored in the changed folder are displayed.
... button
Click this button when specifying an ESF file stored in a folder other than the FP5_PRJ folder in the programming GUI
installation folder. A dialog box for specifying the ESF file will be displayed. Specify the relevant file, and then click
the Open button. Note that the PR5 file specified by the ESF file must be in the specified folder.