Sony L Camcorder User Manual


 
2-1 (E)
HDC-900/950 IMM
Optical contacts (white)
Insert the shorter nose end
Shock absorber portion Handle
2-1. Cleaning of Connector/Cable
It is recommendable to clean the optical contact portions
mentioned below before connecting this unit to the camera
control unit.
. CCU connector of this unit
. Camera connector of the camera control unit
. Optical/Electrical cable
It is also necessary to clean the optical contact portions
mentioned below before using the HDC-950/930 to the
large lens adaptor CA-905L.
. CA cable of a large lens adaptor
. CCU connector of a large lens adaptor
Follow the procedures below for cleaning.
Tools Required
. Alignment sleeve remover HC-001
(for female connector)
Sony P/N: J-6480-010-A
n
Insert the shorter nose end when removing/installing the
alignment sleeve.
Grasp not the shock absorber portion of the remover but
the handle in use.
. Cotton swabs (commercially available)
n
Use the cotton swab with its diameter of around 4 mm.
The cotton swab with its diameter more than 5 mm does
not enough reach to the inner part of the cable, so that
cannot clean the tip of the optical contact.
Cleaning
Male connector
Clean the tip of the white optical contacts by a cotton swab
moistened with alcohol.
Female connector
The optical contacts for female connector are in an unex-
posed state. In cleaning, it is necessary to be exposed by
removing the alignment sleeve in advance. Proceed as
follows.
1. Insert the alignment sleeve remover into the alignment
sleeve in the straight line and turn it clockwise.
Section 2
Service Overview