Sony L Camcorder User Manual


 
4-10 (E)
HDC-900/950 IMM
4-7. Registering the OHB File
4-7. Registering the OHB File
The OHB file is used for storing the maintenance adjustment values of the CCD block and the data will
be stored in the camera. The data can be stored using the setup menu or the MSU (master setup unit).
The items to be stored are the black shading, white shading, ND offset and OHB matrix.
n
As for the setup menu, refer to Section 3.
4-7-1. Storing the Black Shading and White Shading
Storing Using the Setup Menu
(1) Execute the setup menu as follows.
[FILE] [REFERENCE] [STANDARD]
(2) Change the items to the desired value; H SAW, H PARA, V SAW and V PARA of each R/G/B for
each of white shading and black shading.
(3) Set the setup menu as follows.
[FILE] [OHB|FILE] [STORE|FILE]
Storing with MSU
(1) Change the items to the desired value; H SAW, H PARA, V SAW, V PARA of each R/G/B for each
of white shading and black shading.
(2) Press “STORE” of the OHB file.