Toshiba ik-hd5e Security Camera User Manual


 
11
5. 2 Cautions on Connection
When connecting the camera cables, be sure to turn off the camera control unit and any other equipment
connected to it.
For DC power supply connecting to DC IN 12V terminal, use class II DC power supply approved according
to EN60950-1 in Europe. or use UL listed and/or CSA approved ungrounded type AC adaptor with the
specifi cations described below in U.S.A. or Canada.
Power supply voltage : 12V DC ±10%
Current rating : More than 1.5A
Ripple voltage : Less than 50 mV (p–p)
Connector : HR10A–7P–4S by HIROSE electronics Co. Ltd
Pins 1, 2 : 12V
Pins 3, 4 : GND
• If the securing screw on the connector of the camera cable loosens, noise may appear on the screen. Be sure
to tighten the connector completely.
• Only use the specifi c optional camera heads with this camera controller.
The use of any other camera heads may cause damage to the control unit and camera head.
The video signal output of this camera control unit has no function for automatically selecting output according
to the monitor TV. Therefore, be sure to switch the output mode of this camera control unit according to the
monitor as no image will be displayed on the monitor if the camera output mode and the monitor input mode
do not match. For switching, refer to the item 6.6 “Switching of Video Signal Output”.
5. 3 Connector Pin Assignments
The rear panel of the camera control unit has the following connectors:
DC IN 12V; SYNC IN/OUT; 3G/HD-SDI; REMOTE and DVI-D terminal. Use the appropriate cables to connect with
these connectors.
12345
8796
2
10
18
1
9
17
3
11
19
4
12
20
5
13
21
6
14
22
7
15
23
8
16
24
3
4
2
1
ON
OFF
50
59.94
IN
OUT
FORMAT SYNCKEY LOCKDC IN 12V
REMOTE
3G/HD-SDI
SYNC IN/OUT
DVI-D
DC IN 12V terminal REMOTE terminal DVI-D terminal
1 +12V 1 NC 1 Data2- 13 NC
2 +12V 2 TXD 2 Data2+ 14 +5V
3 GND 3 RXD 3 Data2 Shield (GND) 15 GND
4 GND 4 NC 4 NC 16 Hot Plug Detect
5 GND 5 NC 17 Data0-
6 NC 6 NC 18 Data0+
7 NC 7 NC 19 Data0 Shield (GND)
8 NC 8 NC 20 NC
9 NC 9 Data1- 21 NC
10 Data1+ 22 Clock Shield (GND)
11 Data1 Shield (GND) 23 Clock+
12 NC 24 Clock-