Supported Controllers
The following Manchester controllers are compatible with SpeedDome Ultra VII:
Controller Presets
3
Patterns Quick Set Menu Address Range
4
AD2150 64 3 No 1-32
MP48 64 3 No 1-48
AD168/MP168 64 3 No 1-180
AD2050
AD1024
64 3 No 1-1024
AD2052 64 3 No 1-512
This list of controllers is complete as of the time of publication. Other controllers may be supported.
Contact your Sales Representative for current information.
Performance Notes
The following considerations should be made when using the SpeedDome Ultra VII camera dome in
a Manchester environment.
Using Auxiliaries
The dome provides four connections for auxiliaries. When used on a Manchester network, Auxiliaries
1 through 3 are supported. Auxiliary 4 is not supported.
Alarm Inputs
When operating on a Manchester network, the dome can be programmed to respond to any of the four
available alarm inputs. However, the dome cannot transmit alarm input states to the host controller. If
transmitting the alarm input states to the host controller is required, the alarm device must be wired
directly to the host controller.
3
Preset information is stored by the dome, not the host.
4
Additional equipment is required to achieve these numbers.
B–4 SpeedDome Ultra VII Operator's Manual