American Dynamics RAS916LS Security Camera User Manual


 
Performance Notes
The following SpeedDome Ultra VII features are not supported with the Pelco protocols:
PAL video format. This will be supported after further testing.
Long line length applications that require video amplifiers or fiber optics.
Address Settings
The dome must have the correct address setting to operate with Pelco Coaxitron and “P” protocols.
For Coaxitron protocol, the address must be set to 893. For “P” protocol, the address setting is based
upon the baud rate setting:
For 2400 baud, the x100 switch must be set to 6; the x10 and x1 switches may be set to any
number.
For 4800 baud, the x100 switch must be set to 0; the x10 and x1 switches may be set to any
number.
For 9600 baud, the x100 switch must be set to 7, the x10 and x1 switches may set to any number.
Tested Pelco Equipment
The following Pelco equipment has been tested with SpeedDome Ultra VII:
Pelco 9760CTX
Pelco MPT 9500
Supported Pelco Features
SpeedDome Ultra VII supports Left and Right Scan Limits, Auto Scan, Frame Scan and Random
Scan when installed under the Pelco Coaxitron and “P” Protocol environment. The following
commands are supported:
If you want to... Use...
Program the Left Scan Limit
Set Preset 92
Program the Right Scan Limit
Set Preset 93
Activate Auto Scan
Call Preset 99
Activate Frame Scan
Call Preset 98
Activate Random Scan
Call Preset 97
Deactivate Auto, Frame or Random Scan
Call Preset 96
C–4 SpeedDome Ultra VII Operator's Manual