JAI TMC-4200GE Digital Camera User Manual


 
Page 67
TM-4200GE Hardware
Operation
FIGURE 66. Pulse Width Control Trigger
9.3.6 Particle Imaging Velocimetry Fixed Exposure Mode
In Particle Imaging Velocimetry (PIV) Fixed Exposure Mode, when an external trigger is applied, the
first time exposure starts the same as PWC mode does. It lasts a very short period (8µs). The second
time exposure starts during the transferring time of the first image accumulated in the first exposure
time. The second time exposure continues until the first image transfers completely. The second image
is transferred after the second exposure. There is a short period (500ns) between the first exposure and
the second exposure. In order to keep two exposure periods constant, the LDV is reset before the first
image is transferred out.
The maximum trigger frequency in this mode is equal to 1/ (transfer time of two frames + 4µs).
The minimum active period of the external trigger is 5μs
FIGURE 67. PIV Exposure Timing Table