CNT-CLS 1, 2 (Output)
Two contact closure signals (Open collector type) are
output through the Alarm Output connector.
1. Move the cursor to CNT-CLS 1, and select OFF,
ALARM or AUX 1 with the joystick.
The factory default setting is OFF.
When ALARM is selected, TIME OUT appears.
Select an appropriate duration from among 100 MS,
200 MS, 1000 MS (1 s), 2000 MS (2 s) and 4000 MS
(4 s) with the joystick. (unit: s)
The factory default setting is 100 MS. (unit: ms)
Note:
The shorter the duration, the more frequent will
be the detection output.
2. Move the cursor to CNT-CLS 2, then select OFF,
AUX 2 with the joystick.
The factory default setting is OFF.
OFF: Contact closure signals are deactivated.
ALARM: Available for CNT-CLS 1 only. A motion
detection signal is output.
AUX 1(2): An alarm signal is output when the cam-
era receives a command from the controller.
Note:
It is recommended to set the connected external
device to ignore the shorter alarm outputs of 90
ms or less from the camera.
COAXIAL ALARM OUT
Alarm output signals are supplied through the coaxial
cable.
1. Move the cursor to COAX ALM OUT and select ON
or OFF.
2. Press the CAM (SET) button.
The factory default setting is OFF.
ON: The camera sends an alarm output signal after
it turns to a preset position.
OFF: The camera does not send an output signal.
Notes:
The camera ignores alarm inputs during manual
operation.
To download or upload preset data to the system
controller, select “OFF”.
-40-
Alarm Input/Output (ALARM IN/OUT)
Move the cursor to ALARM IN/OUT, and press the CAM
(SET) button. The ALARM IN/OUT submenu appears.
Note:
While the camera is in the AF mode or the lens
moves between WIDE and TELE, alarm input may
be ignored if several alarm inputs are received in
succession.
ALARM IN 1-4
Alarm input signals are supplied from external devices
through the ALARM IN connector to turn the camera to
a preset position.
1. Move the cursor to ALARM IN 1* and select a preset
position or OFF with the joystick, then press the
CAM (SET) button.
The factory default setting is OFF.
* Set ALARM IN 2, 3 and 4 in the same way as
ALARM IN 1.
1 POSI, 2 POSI, 3 POSI and 4 POSI: Preset posi-
tion. If an alarm input is received, the camera
turns to a preset position, and sends an alarm
output signal. The position number corresponds
to the alarm input number (1-1, 2-2, 3-3 and 4-4).
OFF: The camera ignores alarm inputs.
** SPECIAL 1 **
PRIVACY ZONE OFF
PROPO.P/T ON
AREA TITLE ON(USER)
PATROL STOP
ALARM IN/OUT
CLEANING OFF
EL-ZOOM ON
PRESET ALM OFF
IMAGE HOLD OFF
TILT ANGLE 0°
RET
** ALARM IN/OUT **
ALARM IN 1
ALARM IN 2
ALARM IN 3
ALARM IN 4
CNT-CLS 1
TIME OUT
CNT-CLS 2
COAX ALM OUT
RET
OFF
OFF
OFF
OFF
OFF
100MS
OFF
OFF