-41-
● Cleaning (CLEANING)
With CLEANING in the ON position, the camera’s built-
in electromechanical contacts are cleaned at regular
intervals (approx. every 7 days).
A dry contact adversely affects picture quality and
motors operation.
1. Move the cursor to CLEANING and select ON or
OFF with the joystick.
ON: The contacts are cleaned for approx. 1 minute.
"CLEANING" disappears when the cleaning
process is completed.
OFF: No contact cleaning.
Note:
To download or upload preset data to the system
controller, set the cleaning function to “OFF”. If
the cleaning function is activated during the
uploading or downloading process, the upload-
ing or downloading fails.
● Electronic Zoom (EL-ZOOM)
The electronic zoom magnifies a scene 10-fold. With a
22-fold optical zoom lens, the camera is capable of
220-fold zoom.
1. Move the cursor to EL-ZOOM and select ON or OFF
with the joystick, and then press the CAM (SET) but-
ton.
** SPECIAL 1 **
PRIVACY ZONE OFF
PROPO.P/T ON
AREA TITLE ON(USER)
PATROL STOP
ALARM IN/OUT
CLEANING ON
EL-ZOOM ON
PRESET ALM OFF
IMAGE HOLD OFF
TILT ANGLE 0°
RET
CLEANING
** SPECIAL 1 **
PRIVACY ZONE OFF
PROPO.P/T ON
AREA TITLE ON(USER)
PATROL STOP
ALARM IN/OUT
CLEANING ON
EL-ZOOM ON
PRESET ALM OFF
IMAGE HOLD OFF
TILT ANGLE 0°
RET
ON: 10 - fold electronic zoom is available with the
ZOOM switch on the controller.
OFF: The electronic zoom function is not used.
Notes:
•A scene magnified by the electronic zoom func-
tion may be inferior in picture quality to a non-
magnified one.
• The electronic zoom does not function in the pre-
set position setting mode.
• When trying to set preset positions directly from
the WV-CU360 System Controller while ON is set
for the electronic zoom function and the dis-
played scene is magnified at more than x22, the
INHIBIT indication will be displayed. In this case,
you need to set the electronic zoom function
temporarily to OFF.
● Preset Alarm (PRESET ALM)
An alarm output is sent when the camera moves to the
designated position depending on the mode.
1. Move the cursor to PRESET ALM and select ON or
OFF.
ON: Alarm signals are output in the following cases.
• When a preset positioning sequence is complet-
ed while AUTO MODE is set to SEQ.
• When a preset positioning sequence is complet-
ed while AUTO MODE is set to SORT.
• When the self-return function has returned the
camera to its home position.
• Positioning is completed for a position request
command.
• Positioning to the designated point is completed
for ALARM IN/OUT.
• When positioning to the starting point is complet-
ed while AUTO MODE is set to AUTO PAN.
• When positioning to the starting point is complet-
ed while PATROL is set to PLAY.
OFF: Alarm signals are not output.
Notes:
• Select OFF when the camera downloads or
uploads the preset data.
• When selecting "ON", set "AUTO" for "ALARM
DATA" on the RS485 SETUP menu (page 19).
** SPECIAL 1 **
PRIVACY ZONE OFF
PROPO.P/T ON
AREA TITLE ON(USER)
PATROL STOP
ALARM IN/OUT
CLEANING OFF
EL-ZOOM ON
PRESET ALM ON
IMAGE HOLD OFF
TILT ANGLE 0°
RET