Panasonic AW- PH350 Digital Camera User Manual


 
19
Connections
$Head connector panel
The camera and lens control cables are connected to this panel.
1ND/EXT connector
This is for controlling the ND filter and
lens extender of the power lens unit.
Connect it when using a power lens unit
equipped with an ND filter and lens
extender function.
4CAMERA I/F connector
This is for convertible camera control.
Connect this to the REMOTE connector
on the camera.
Use a pan-tilt head cable (optional
accessory) suitable for the application
for the connecting cable.
(See pages 23 to 28.)
2LENS I/F connector
This is for controlling the zoom/focus
functions of the power lens unit.
Connect the remote (zoom/focus) control
cable of the power lens unit here.
3SDI IN connector
This is for SDI signal input.
Using a coaxial cable (BELDEN 8281),
connect this with the SDI OUT connector
of an SDI card (AW-PB304), etc.
installed in the convertible camera.
AF
BE
CD
(As viewed from cable end)
ND signal
ND return
CVCC (+15V)
CGND
EXT return
EXT signal